Case study · Heritage

Heritage masonry & lintel remediation — interwar apartment block

Corroded steel lintels replaced and masonry repointed in analysed lime mortar under heritage permit conditions, with the original face brickwork retained throughout.

CS-03 / ELEVATION STREET Heritage masonry & lintel remediation — interwar apartment block
Drag to compare pre-works condition against completed remediation.

Problem

A significant interwar brick apartment building presented stepped cracking over the window heads to the street elevation, consistent with lintel jacking, in which corroding steel lintels expand and lift the masonry above. A previous repair had repointed the cracks in hard cement mortar. This concealed the progression of the defect and damaged the brick arrises.

Diagnosis

Investigation openings at four representative window heads confirmed corroding mild-steel lintels with heavy section loss, plus cavity ties corroded at the same detail line. Mortar analysis established the original lime-rich mix for permit-compliant repointing. The condition report and proposed methodology were prepared with the heritage consultant to support the owners corporation’s heritage permit application.

Method

Sequenced masonry support and dismantling above each affected opening, brick-by-brick with units numbered for reinstatement in position. Corroded lintels replaced with galvanised steel sections isolated from the masonry; stainless cavity ties installed across affected zones. Reinstatement and full repointing in analysed lime mortar, with a sample panel approved by the heritage consultant before proceeding. Cement-mortar patches removed and repointed correctly across both street elevations.

Outcome

Permit conditions were discharged with full photographic documentation. Every reclaimed brick was reinstated in its original position, and the completed elevation retains its original fabric.

Representative case study, illustrating our investigation method and reporting format.

Arrange a site assessment

A written condition report with an itemised scope, prepared to a standard your committee, consulting engineer or board can act on.